# DiffDock Custom Inference Configuration Template # Copy and modify this file to customize inference parameters # Model paths (usually don't need to change these) model_dir: ./workdir/v1.1/score_model confidence_model_dir: ./workdir/v1.1/confidence_model ckpt: best_ema_inference_epoch_model.pt confidence_ckpt: best_model_epoch75.pt # Model version flags old_score_model: false # Set to true to use original DiffDock instead of DiffDock-L old_filtering_model: true # Inference steps inference_steps: 20 # Increase for potentially better accuracy (e.g., 25-30) actual_steps: 19 no_final_step_noise: true # Sampling parameters samples_per_complex: 10 # Increase for difficult cases (e.g., 20-40) sigma_schedule: expbeta initial_noise_std_proportion: 1.46 # Temperature controls - Adjust these to balance exploration vs accuracy # Higher values = more diverse predictions, lower values = more focused predictions # Sampling temperatures temp_sampling_tr: 1.17 # Translation sampling temperature temp_sampling_rot: 2.06 # Rotation sampling temperature temp_sampling_tor: 7.04 # Torsion sampling temperature (increase for flexible ligands) # Psi angle temperatures temp_psi_tr: 0.73 temp_psi_rot: 0.90 temp_psi_tor: 0.59 # Sigma data temperatures temp_sigma_data_tr: 0.93 temp_sigma_data_rot: 0.75 temp_sigma_data_tor: 0.69 # Feature flags no_model: false no_random: false ode: false # Set to true to use ODE solver instead of SDE different_schedules: false limit_failures: 5 # Output settings # save_visualisation: true # Uncomment to save SDF files # ============================================================================ # Configuration Presets for Common Use Cases # ============================================================================ # PRESET 1: High Accuracy (slower, more thorough) # samples_per_complex: 30 # inference_steps: 25 # temp_sampling_tr: 1.0 # temp_sampling_rot: 1.8 # temp_sampling_tor: 6.5 # PRESET 2: Fast Screening (faster, less thorough) # samples_per_complex: 5 # inference_steps: 15 # temp_sampling_tr: 1.3 # temp_sampling_rot: 2.2 # temp_sampling_tor: 7.5 # PRESET 3: Flexible Ligands (more conformational diversity) # samples_per_complex: 20 # inference_steps: 20 # temp_sampling_tr: 1.2 # temp_sampling_rot: 2.1 # temp_sampling_tor: 8.5 # Increased torsion temperature # PRESET 4: Rigid Ligands (more focused predictions) # samples_per_complex: 10 # inference_steps: 20 # temp_sampling_tr: 1.1 # temp_sampling_rot: 2.0 # temp_sampling_tor: 6.0 # Decreased torsion temperature # ============================================================================ # Usage Example # ============================================================================ # python -m inference \ # --config custom_inference_config.yaml \ # --protein_ligand_csv input.csv \ # --out_dir results/